ContinuousRead class provides access to continuous scanning related parameters.
@Deprecated
public class ScannerConfig.ReaderParams.ReaderSpecific.ContinuousRead
extends java.lang.Object
| Modifier and Type | Field and Description | 
|---|---|
int | 
differentSymbolTimeout
Deprecated. 
 
We recommend using the new fields shown below in your new applications.
 
 For Camera Scanner:
  
ScannerConfig.ReaderParams.ReaderSpecific.CameraSpecific.differentSymbolTimeout
 For Imager Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.ImagerSpecific.differentSymbolTimeout
 
 For Laser Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.LaserSpecific.differentSymbolTimeout
 
 This setting is used to prevent the scanner from decoding another symbol within this time interval (applicable only when  
 isContinuousScan = true). The user may want to prevent decoding too quickly and set an interval that the user can aim 
 before decoding the next barcode. A value of 0 means no interval is required between two successive reads.
 Boundary values are 0 to 5000 in milliseconds in 500 increments such as 0, 500, 1000... etc | 
boolean | 
isContinuousScan
Deprecated. 
 
We recommend using the new fields shown below in your new applications.
 
 For Camera Scanner:
  
ScannerConfig.ReaderParams.ReaderSpecific.CameraSpecific.aimType
 
 For Imager Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.ImagerSpecific.aimType
 
 For Laser Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.LaserSpecific.aimType
 
 Scan continuously; In this mode once the trigger is pulled the user can continue scanning barcodes without releasing the trigger 
 as long as new reads are submitted as soon as the earlier read is satisfied. This mode is useful when the user wants to perform 
 rapid scanning. To provide better control over this feature we have added the two new reader parameters (SameSymbolTimeout, 
 DifferentSymbolTimeout) that are associated with continuous reads. These reader parameters are available in both ImagerSpecific 
 and LaserSpecific classes. 
 NOTE: The following must be considered when using this AIM_TYPE.CONTINUOUS_READ mode. 
 1. After each successful read, the application will have to submit a new read for rapid triggering. 
 2. It is recommended that the Picklist mode be enabled for the imager-class scanners. 
 3. When using this mode, the IMAGER_SPECIFIC.VFFeedback parameter will be ignored and no viewfinder feedback will be provided. 
 It is similar to setting IMAGER_SPECIFIC.VFFeedback to VIEWFINDER_FEEDBACK.VIEWFINDER_MODE_DISABLED 
 4. If the IMAGER_SPECIFIC.VFMode parameter is set to VIEWFINDER_MODE.VIEWFINDER_MODE_DYNAMIC_RETICLE, then this continuous read mode will be ignored | 
int | 
sameSymbolTimeout
Deprecated. 
 
We recommend using the new fields shown below in your new applications.
 
 For Camera Scanner:
  
ScannerConfig.ReaderParams.ReaderSpecific.CameraSpecific.sameSymbolTimeout
 For Imager Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.ImagerSpecific.sameSymbolTimeout
 
 For Laser Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.LaserSpecific.sameSymbolTimeout
 
 This setting is used to prevent the scanner driver from decoding the same symbol within this time interval (applicable only when 
 isContinuousScan = true). Basically in the continuous mode the user can perform rapid scan and to prevent the 
 user from decoding the same barcode twice user can set this value to an appropriate interval (in milliseconds). A value of 0 means 
 no interval is required between two successive reads.
 Boundary values are 0 to 5000 in milliseconds in 500 increments such as 0, 500, 1000... etc | 
| Constructor and Description | 
|---|
ContinuousRead()
Deprecated.  
  | 
@Deprecated public boolean isContinuousScan
ScannerConfig.ReaderParams.ReaderSpecific.CameraSpecific.aimType
 
 For Imager Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.ImagerSpecific.aimType
 
 For Laser Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.LaserSpecific.aimType
 
 Scan continuously; In this mode once the trigger is pulled the user can continue scanning barcodes without releasing the trigger 
 as long as new reads are submitted as soon as the earlier read is satisfied. This mode is useful when the user wants to perform 
 rapid scanning. To provide better control over this feature we have added the two new reader parameters (SameSymbolTimeout, 
 DifferentSymbolTimeout) that are associated with continuous reads. These reader parameters are available in both ImagerSpecific 
 and LaserSpecific classes. 
 NOTE: The following must be considered when using this AIM_TYPE.CONTINUOUS_READ mode. 
 1. After each successful read, the application will have to submit a new read for rapid triggering. 
 2. It is recommended that the Picklist mode be enabled for the imager-class scanners. 
 3. When using this mode, the IMAGER_SPECIFIC.VFFeedback parameter will be ignored and no viewfinder feedback will be provided. 
 It is similar to setting IMAGER_SPECIFIC.VFFeedback to VIEWFINDER_FEEDBACK.VIEWFINDER_MODE_DISABLED 
 4. If the IMAGER_SPECIFIC.VFMode parameter is set to VIEWFINDER_MODE.VIEWFINDER_MODE_DYNAMIC_RETICLE, then this continuous read mode will be ignored@Deprecated public int sameSymbolTimeout
ScannerConfig.ReaderParams.ReaderSpecific.CameraSpecific.sameSymbolTimeout
 For Imager Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.ImagerSpecific.sameSymbolTimeout
 
 For Laser Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.LaserSpecific.sameSymbolTimeout
 
 This setting is used to prevent the scanner driver from decoding the same symbol within this time interval (applicable only when 
 isContinuousScan = true). Basically in the continuous mode the user can perform rapid scan and to prevent the 
 user from decoding the same barcode twice user can set this value to an appropriate interval (in milliseconds). A value of 0 means 
 no interval is required between two successive reads.
 Boundary values are 0 to 5000 in milliseconds in 500 increments such as 0, 500, 1000... etc@Deprecated public int differentSymbolTimeout
ScannerConfig.ReaderParams.ReaderSpecific.CameraSpecific.differentSymbolTimeout
 For Imager Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.ImagerSpecific.differentSymbolTimeout
 
 For Laser Scanner:
 ScannerConfig.ReaderParams.ReaderSpecific.LaserSpecific.differentSymbolTimeout
 
 This setting is used to prevent the scanner from decoding another symbol within this time interval (applicable only when  
 isContinuousScan = true). The user may want to prevent decoding too quickly and set an interval that the user can aim 
 before decoding the next barcode. A value of 0 means no interval is required between two successive reads.
 Boundary values are 0 to 5000 in milliseconds in 500 increments such as 0, 500, 1000... etc